MIMOS Berhad
INSPECTRA Inline NIR Analyser
INSPECTRA CPO Β· INSPECTRA Lab Β· INSPECTRA Pro
INSPECTRA is a Malaysian-developed inline near-infrared (NIR) analyser for real-time quality measurement of crude palm oil (CPO). Unlike laboratory sampling methods, INSPECTRA measures directly in the process pipeline without any sample extraction β providing continuous, real-time quality data for process optimisation.
Technical Specifications
| Measurement Parameters | FFA (Free Fatty Acid), Moisture, DOBI, Iodine Value |
| Measurement Method | Near Infrared (NIR) Inline β no sample extraction |
| Response Time | < 30 seconds |
| FFA Range | 0.5% β 10% |
| Moisture Range | 0.01% β 1.0% |
| Temperature Range | 60Β°C β 95Β°C (process fluid) |
| Output | 4β20mA, RS485 Modbus, Ethernet |
| HMI | Touchscreen operator interface |
| Developed By | MIMOS Berhad (Malaysia) |
Applications
Palm oil mill CPO line quality monitoring (FFA, moisture, DOBI, iodine value). Suitable for installation at digester discharge, screw press outlet, clarification tank feed and CPO dispatch points.
More Products
AutomationSiemens S7-1200Compact PLC for small-medium automation
AutomationSiemens S7-300/400Mid and high-end PLC systems
AutomationWecon HMICost-effective touch panel HMI
Sensor & TXINSPECTRA NIRInline CPO quality analyser
Sensor & TXRheonics ViscometerInline viscosity and density
Drive & InverterSINAMICS VFDVariable frequency drives